top of page

OPTIMUM SERIES
80-240 kW LEVEL 3 DC FAST CHARGER
The Optimum Series (80–240 kW) is a modular DC fast charger built for fleets, commercial sites, and large public networks, delivering scalable high-power charging with reliable performance. It enables seamless, app-free, tap-to-charge payments while offering real-time monitoring and remote management. Designed for durability across diverse environments, it ensures consistent uptime with minimal maintenance through OTA updates, and revenue at scale




EASY ACCESS FOR
COMPONENT
MAINTENANCE
ROBUST
CONDENSATION
MITIGATION
THIN PROFILE
DESIGN
DAISY CHAIN FOR
MULTIPLE CHARGERS
AT ONE LOCATION
POWER COATED
ALUMINUM BODY
12" TOUCHSCREEN DISPLAY
PAYMENT
TERMINAL
SEPERATE INPUT
BREAKER ACCESS
PANEL FOR QUICK AND
SAFE
DE-ENERGIZING
Technical Specs
Available Power level
80 kW up to 240kW
Unit Dimensions
87.70” Height
9.50” Width
33.40” Depth
Plug Configurations


Site Host Support

AC INPUT
Voltage Range: 340V-528V 3Φ (3P+PE)
Rated Voltages:
480V - 3Φ (3P+PE)
Max. Continuous Input Current At 480V Volts: 240kW: 300A, 240kW:250A, 160kW: 200A, 120kW: 150A, 80kW: 100A
Frequency 50Hz/60Hz
Power Factor Greater Than 0.99
Full Load Efficiency> 97.5%
PROTECTION
Input Protection: SPD, OCP, OVP, OTP ,OPP
Output Protection: IMD,OCP, OVP, OTP, SCP
COMMUNICATIONS
External: Ethernet and 4G
Internal: CAN bus/Ethernet/RS485/RS232
DC OUTPUT
Output Voltage Range CCS: 150~1000Vdc NACS: 150~1000Vdc
Continuous Output Current CCS, NCC: 250A/350A, NACS, NCC: 250A/350A
Connector Options (Based on Customer Specs):
2 CCS/2 NACS/1 CCS and 1 NACS
Voltage Accuracy +/- 0.5%
Current Accuracy +/-1%
ENVIRONMENTAL
Rated Temperature Range -58F to 50F, Power
Derating Starts at 126F
Operating Temperature Range -76F to 158F
Humidity 5%~95% RH, Non-Condensing
Altitude ≦ 6,562 FT (2000m)
Aluminum Type 3R Rainproof Enclosure
Air-Cooled System
USER INTERFACE + CONTROL
PCI Compliant Payment Terminal Optional (Tap/Insert/Swipe/NFC)
User Authentication RFID: Supports ISO 14443A/B
OCPP 1.6J and 2.0.1
REGULATION
Compliance UL 2202, UL 2231-1, UL2231 - 2, UL50E, CSA C22.2 No
346:22,cCSAus
Charging Interface ISO15118 (CCS1/NACS)
ACT INPUT
Voltage: 208/240 VAC
Breaker Ratings:
32A- Rating 40A
40A- Rating 50A
48A- Rating 60A
Single Connector: 3 Wire (L1,L2 & G)Double Connector: 5 Wire (L1, L1, L2, L2 & G)
AC OUTPUT PER CONNECTOR
7.7 kW at 240VAC
6.6 kW at 208VAC
CONNECTORS
SAE J1772 Type 1
OPERATING TEMPERTURE:
-20C to 50 C
- 4° F to +122° F
CERTIFICATIONS
TUV Rheinland UL 2231-1, UL 2231-2, UL 2594
ENERGY STAR- Double Ports Only
COMMUNICATIONS
TUV Rheinland UL 2231-1, UL 2231-2, UL 2594
ENERGY STAR- Double Ports Only
CHARGE TIME FOR AVERAGE EV WITH 80 kWh
CAPACITY GOING FROM 20-80%
32A | 6.25Hr
40A | 5Hr
48A | 4.2Hr
COMMUNICATIONS
Cellular
Ethernet
CORD LENGTH
18 Feet
PROTOCAL
OCPP 1.6J
ENCLOSURE
Type 3R Aluminum
USER INTERFACE
LED Indicators
RFID Card Reader
OPTIONS
Wall Bracket
Pedestal Mount
Branded Door Graphics
ACT INPUT
Voltage Range: 340V-528V 3Φ (3P+PE)
Rated Voltages:
380V - 400V - 415V - 440V - 480V 3Φ (3P+PE)
Max. Input Current 54A, 70A Breaker Included In Pedestal
Frequency 50Hz/60Hz
Power Factor Greater Than 0.99
Full Load Efficiency> 95%
PROTECTION
Input Protection: SPD, OCP, OVP, OTP , OPPOutput Protection: IMD,OCP, OVP, OTP, SCP
COMMUNICATIONS
External: Ethernet and 4G
Internal: CAN bus/Ethernet/RS485/RS232
DC OUTPUT
Output Voltage Range CCS: 150~1000Vdc NACS: 150~1000Vdc
Max. Output Current CCS: 100A NACS: 100A
Connector Options (Based on Customer Specs):
2 CCS/2 NACS/1 CCS and 1 NACS
Voltage Accuracy +/- 0.5%
Current Accuracy +/-1%
ENVIRONMENTAL
Rated Temperature Range -58F to 120F, Power
Derating Starts at 126F
Operating Temperature Range -58F to 158F
Humidity 5%~95% RH, Non-Condensing
Altitude ≦ 6,562 FT
Aluminum Type 3R Rainproof Enclosure
Air-Cooled System
USER INTERFACE + CONTROL
Stop Button With RGB Indicators
PCI Compliant Payment Terminal (Tap/Insert/Swipe/NFC)
User Authentication RFID (Version with Payment Terminal Only): Supports ISO 14443A/B
OCPP 1.6J and 2.0.1 (Networked Version)
REGULATION
Compliance UL 2202, UL 2331-1, UL2231 - 2, UL50E, CSA C22.2 No
107.1/CSA C22.2 No 281.1-12/CSA C22.2 No 281.2-12, cCSAus
Charging Interface ISO15118 (CCS1/NACS)
bottom of page